beautypg.com

Festo Контроллер позиционирования CPX-CMAX User Manual

Page 88

background image

4. Commissioning

4−10

Festo P.BE−CPX−CMA X−SYS−EN en 0908NH

Search for axis at

axis interface

Power on

Valve and displacement

encoder missing

Valve and displacement

encoder OK

Axis found

Axis not found

Target configuration not

present

Target configuration

present

Target configuration

present

Wait for

configuration

Controller

ready

Malfunction

PNU 1192:02 = 0

1

2

3

1

Initial start−up is complete, CMAX is
ready for operation

2

For malfunctions, see chapter 5

3

Status when switched on for first time
(delivery status or after data reset):
Wait for initial start−up. For display, see
Tab. 4/1

Fig. 4/1:

Switch−on behaviour

Display

Description

C00

Wait for the parameterisation of the system of
measurement units.

C01

Wait for drive type parameterisation.

C02

Wait for axis data parameterisation.

C03

Wait for movement test to be carried out.

Tab. 4/1: Display during commissioning

An overview of status displays can be found in section 5.4.2.