2 status display, Status display – Festo Контроллер позиционирования CPX-CMAX User Manual
Page 158
5. Diagnostics and error handling
5−36
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
5.4.2
Status display
Possible status information
No.
Status display
Additional
Information
Description
Example
1
." flashing
An
Initialisation of components at the axis interface n
n
nn
After initialising components at the axis interface,
the firmware version is displayed for about 1 s
(e.g. V 1.00).
2
C
nn
Parameterisation phase, with current status nn
3
0
nn
Initialisation is successfully completed. There is no
enable. Current operating mode status display: nn
4
1
nn
Ready for operation, current operating mode in
status display: nn
5
2
nn
Record select operating mode, last or current
positioning record nn
About 1:
Point flashes during the entire initialisation phase.
About 2:
Parameterisation phase, status in
additional information:
00: Wait for system of units
01: Wait for drive type
02: Wait for axis data
03: Wait for movement test
About 3 and 4:
Display of the operating mode in
additional information:
02: Record select
03: Direct mode
04: Commissioning
0P: Parametrising