5. Diagnostics and error handling
5−38
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
Possible status information
No.
Example
Description
Additional
Information
Status display
13
P
nn
Parameterisation is active, current parameter nn
PNU/100
14
E
nn
Error active, error number: nn
0x: Configuration error
1x: Execution error
2x: Positioning record error
3x: Regulation error
4x: System error A
5x: System error B
6x: Valve error
7x: Controller error
8x: Displacement encoder error
15
ć" flashes
ć ć" flashes
Device data reset.
At the end of resetting, the CMAX must be
switched off and back on again.
16
." flashes
ć
Decimal flashes at 10 Hz if the job is active
(MC = 0).
About 13:
If a parameter is changed acyclically or in parametrising operating mode, the
corresponding PNU / 100 is displayed for 1 second. For accessing a reading
parameter or parameter access via the diagnostic interface (FCT CMAX plug−in),
there is no display. If there is a new writing parameter access within this display
time window, the new PNU / 100 is displayed and the display time starts over (1 s).
If no parameter is being changed yet in parametrising operating mode or if the
display time has expired, −−" is displayed in the additional information.
Tab. 5/6: Status information display
After switching on, the decimal point flashes during the entire
initialisation phase.