beautypg.com

3/1, fig – Festo Контроллер позиционирования CPX-CMAX User Manual

Page 76

background image

3. Electrical installation

3−16

Festo P.BE−CPX−CMA X−SYS−EN en 0908NH

Valve load voltage supply can be disconnected
separately (Fig. 3/2)

In the example, CMAX, and therefore the positioning system,
are supplied via the system supply

1.

The MPA pneumatics are supplied via the valve supply

2

(only permitted with MPA electronic modules of type
VMPA..−FB−EMG−...). The MPA pneumatics can be switched
off at all poles (galvanically isolated).

8DI

8DI

4DO

CMAX

8 A

8 A

1

MPA

2

1 2 34

1 23 4

Schematic representation:

24ĂV

VAL

0ĂV

VAL

24ĂV

OUT

0ĂV

OUT

24ĂV

EL/SEN

0ĂV

EL/SEN

1

Interlinking block with system supply (supplied the CMAX)

2

Interlinking block with additional supply for valves (supplies MPA pneumatics)

Fig. 3/2:

Separate power supply for MPA pneumatics (example)