4. Commissioning
4−27
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
4. Step: Record is running
After the record start with SPOS.ACK = 1 has been detected,
CPOS.START can be reset.
Control bytes (step 4)
Bit
B7
B6
B5
B4
B3
B2
B1
B0
CCON
OPM2
OPM1
LOCK
ć
RESET
BRAKE
STOP
ENABLE
Byte 1
0
0
0
0
0
1/0
1
1
CPOS
ć
CLEAR
TEACH
JOGN
JOGP
HOM
START
HOLD
Byte 2
0
0
0
0
0
0
0
0
Record no. Record number of the next record to be started. Any
Byte 3
x
x
x
x
x
x
x
x
res.
Byte 4 ... 8: reserved (= 0)
The running record is signalled with SPOS.MC = 0.
Resetting CPOS.START is signalled back with SPOS.ACK = 0.
Status bytes (step 4)
Bit
B7
B6
B5
B4
B3
B2
B1
B0
SCON
OPM2
OPM1
FCT_MMI
24VL
FAULT
WARN
OPEN
ENABLED
Byte 1
0
0
0
1
0
0
1
1
SPOS
REF
STILL
DEV
MOV
TEACH
MC
ACK
HOLD
Byte 2
1
x
x
x
x
x
0
0
Record no. Acknowledgement of last started record: 36
Byte 3
0
0
1
0
0
1
0
0
RSB
ć
ć
XLIM
VLIM
RCE
COM1
RCC
RC1
Byte 4
x
x
x
x
x
x
x
x
Primary
actual
value
Byte 5 ... 8: Acknowledgement of the actual value of the position or force in the configured
system of units.