ADTRAN Atlas 550 User Manual
Page 74

Chapter 6. System Control Terminal Menus
6-12
ATLAS 550 User Manual
61200305L1-1
the
S
TATION
T
YPE
as
T-W
ATCH
M
GMT
and append the
C
OMMUNITY
N
AME
with
“.ADLP ADDRESS.” Within the SNMP trap packet, this field is automati-
cally updated before it is sent to the management station.
DS1 C
URRENT
P
ERF
T
HRESHOLDS
Write security: 2; Read security: 5
Defines performance threshold values for DS1 Line and Path statistics
recorded in a 15-minute interval. If a statistic value exceeds its threshold
value, then the corresponding Alert Trap will be sent if the alert event is
armed and Alert Traps are enabled. These thresholds apply to all DS1 inter-
faces in the system.
C
URRENT
ES T
HRSH
The DS1 performance monitor Threshold Value for the Current 15 minute
Errored Seconds (ES) parameter. The default value is 65 for an approximate
BER level of 10E-5.
C
URRENT
SES T
HRSH
The DS1 performance monitor Threshold Value for the Current 15 minute
Severely Errored Seconds (SES) parameter. The default value is 10 for an
approximate BER level of 10E-5.
C
URRENT
SEFS T
HRSH
The DS1 performance monitor Threshold Value for the Current 15 minute
Severely Errored Framing Seconds (SEFS) parameter. The default value is 2
for an approximate BER level of 10E-5.
C
URRENT
UAS T
HRSH
The DS1 performance monitor Threshold Value for the Current 15 minute
Unavailable Seconds (UAS) parameter. The default value is 10 for an
approximate BER level of 10E-5.
C
URRENT
CSS T
HRSH
The DS1 performance monitor Threshold Value for the Current 15 minute
Controlled Slip Seconds (CSS) parameter. The default value is 1 for an
approximate BER level of 10E-5.
C
URRENT
PCV T
HRSH
(D4)
The DS1 performance monitor Threshold Value for the Current 15 minute
Path Code Violation (PCV) parameter, when the Line Type is Super Frame
(AT&T D4 format) DS1. The default value is 72 Framing errors for an
approximate BER level of 10E-5.
C
URRENT
PCV T
HRSH
(ESF)
The DS1 performance monitor Threshold Value for the Current 15 minute
Path Code Violations (PCV) parameter, when the Line Type is Extended
Super Frame (ESF) DS1. The default value is 13,296 CRC errors for an
approximate BER level of 10E-5.
C
URRENT
LES T
HRSH
The DS1 performance monitor Threshold Value for the Current 15 minute
Line Errored Seconds (LES) parameter. The default value is 65 for an
approximate BER level of 10E-5.