Network connection – ADTRAN Atlas 550 User Manual
Page 43

Chapter 2. Installation
61200305L1-1
ATLAS 550 User Manual
2-7
Table 2-5 shows the pinout for the External Alarm Relay connector.
Network Connection
The ATLAS 550 provides two Network Interface Slots that allow different
types of interfaces to be used. Currently only a T1 Network Interface is avail-
able. In the remainder of this manual, discussions about the Network Inter-
face Module refer to the T1 Network Interface Module. The T1 Network
Interface (NI) port complies with the applicable ANSI and AT&T
®
stan-
dards. The T1 Network Interface Module provides the following functions:
•
AMI or B8ZS coding
•
Manual line build-out
•
D4 or ESF framing
•
Network performance monitoring and reporting
•
Test loopbacks with QRSS generation and checking
•
Extensive self-testing
The network connections follow, with the pinouts shown in Table 2-6 and
Table 2-7 on page 2-8.
Table 2-5. External Relay Monitor Connector Pinout
Pin
Name
Description
1
Alarm Out Outputs EIA-232 level signal for connection to external
alarm contacts.
2
Alarm In
Monitors signal coming from external alarm contacts.
Connector type
(USOC) RJ-48C
Part number
AMP# 555164-2
Table 2-6. Network RJ-48C Pinout
PIN
NAME
DESCRIPTION
1
R1 RXDATA-RING
Receive data from the network
2
T1 RXDATA-TIP
Receive data from the network
3
UNUSED
—
4
R TXDATA-RING
Transmit data toward the network
5
T TXDATA-TIP
Transmit data toward the network
6, 7, 8
UNUSED
—