beautypg.com

Network connection – ADTRAN Atlas 550 User Manual

Page 43

background image

Chapter 2. Installation

61200305L1-1

ATLAS 550 User Manual

2-7

Table 2-5 shows the pinout for the External Alarm Relay connector.

Network Connection

The ATLAS 550 provides two Network Interface Slots that allow different
types of interfaces to be used. Currently only a T1 Network Interface is avail-
able. In the remainder of this manual, discussions about the Network Inter-
face Module refer to the T1 Network Interface Module. The T1 Network
Interface (NI) port complies with the applicable ANSI and AT&T

®

stan-

dards. The T1 Network Interface Module provides the following functions:

AMI or B8ZS coding

Manual line build-out

D4 or ESF framing

Network performance monitoring and reporting

Test loopbacks with QRSS generation and checking

Extensive self-testing

The network connections follow, with the pinouts shown in Table 2-6 and
Table 2-7 on page 2-8.

Table 2-5. External Relay Monitor Connector Pinout

Pin

Name

Description

1

Alarm Out Outputs EIA-232 level signal for connection to external

alarm contacts.

2

Alarm In

Monitors signal coming from external alarm contacts.

Connector type

(USOC) RJ-48C

Part number

AMP# 555164-2

Table 2-6. Network RJ-48C Pinout

PIN

NAME

DESCRIPTION

1

R1 RXDATA-RING

Receive data from the network

2

T1 RXDATA-TIP

Receive data from the network

3

UNUSED

4

R TXDATA-RING

Transmit data toward the network

5

T TXDATA-TIP

Transmit data toward the network

6, 7, 8

UNUSED