Appendix A. System Event Logging

A-2

ATLAS 550 User Manual

61200305L1-1

Table A-1. System Event

Event

Category

Console Log String

-24 V power supply is functioning normally
again

Critical

“-24 V Power Failure Cleared”

-24 V power supply is not operating properly Critical

“-24 V Power Failure”

-58 V power supply is functioning normally
again

Critical

“-58 V Power Failure Cleared”

-58 V power supply is not operating properly Critical

“-58 V Power Failure”

ACO switch pressed

Minor

ACO Switch pressed

Alarm detected on External Alarm Monitor

Minor

External Alarm Detected

ATLAS configuration file loaded into the
system and activated

Critical

System Configuration Uploaded

Console login failure

a

a. Three consecutive login attempts were attempted and failed.

Minor

Login Failure

Corrupted firmware

Critical

Firmware invalid

External alarm cleared

Minor

External Alarm Cleared

Flash download failed

Critical

Firmware update failed

Flash download successful

Info

Firmware update completed

Internal system temperature has cooled

below 70

o

C

Critical

>70 Internal Temperature Warning
Cleared

Internal system temperature has cooled

below 85

o

C

Critical

>85 Internal Temperature Warning
Cleared

Internal system temperature is greater than

70

o

C

Critical

>70C Internal Temperature Warning

Internal system temperature is greater than

85

o

C

Critical

>85C Internal Temperature Warning

Module found

Info

Module Found

Module removed or not responding

Warning

Module Not Responding

Neither the primary nor the backup are valid

Minor

Timing source changed to Internal

SNMP authentication failure

b

b. Generated if the ATLAS receives an SNMP request from an SNMP manager defined in theATLAS SNMP com-

munities list but with a community name that does not match the community name defined in the SNMP commu-
nities list.

Info

SNMP Authentication Failure

System cold start

c

c. Generated five seconds after the completion of system initialization.

Normal

Cold

The primary source is not Backup valid

Minor

Timing source changed to Backup

The timing source changed to primary

Minor

Timing source changed to Primary

Unable to program module

Minor

Not responding to programming