ADTRAN Atlas 550 User Manual
Page 204

Appendix A. System Event Logging
A-2
ATLAS 550 User Manual
61200305L1-1
Table A-1. System Event
Event
Category
Console Log String
-24 V power supply is functioning normally
again
Critical
“-24 V Power Failure Cleared”
-24 V power supply is not operating properly Critical
“-24 V Power Failure”
-58 V power supply is functioning normally
again
Critical
“-58 V Power Failure Cleared”
-58 V power supply is not operating properly Critical
“-58 V Power Failure”
ACO switch pressed
Minor
ACO Switch pressed
Alarm detected on External Alarm Monitor
Minor
External Alarm Detected
ATLAS configuration file loaded into the
system and activated
Critical
System Configuration Uploaded
Console login failure
a
a. Three consecutive login attempts were attempted and failed.
Minor
Login Failure
Corrupted firmware
Critical
Firmware invalid
External alarm cleared
Minor
External Alarm Cleared
Flash download failed
Critical
Firmware update failed
Flash download successful
Info
Firmware update completed
Internal system temperature has cooled
below 70
o
C
Critical
>70 Internal Temperature Warning
Cleared
Internal system temperature has cooled
below 85
o
C
Critical
>85 Internal Temperature Warning
Cleared
Internal system temperature is greater than
70
o
C
Critical
>70C Internal Temperature Warning
Internal system temperature is greater than
85
o
C
Critical
>85C Internal Temperature Warning
Module found
Info
Module Found
Module removed or not responding
Warning
Module Not Responding
Neither the primary nor the backup are valid
Minor
Timing source changed to Internal
SNMP authentication failure
b
b. Generated if the ATLAS receives an SNMP request from an SNMP manager defined in theATLAS SNMP com-
munities list but with a community name that does not match the community name defined in the SNMP commu-
nities list.
Info
SNMP Authentication Failure
System cold start
c
c. Generated five seconds after the completion of system initialization.
Normal
Cold
The primary source is not Backup valid
Minor
Timing source changed to Backup
The timing source changed to primary
Minor
Timing source changed to Primary
Unable to program module
Minor
Not responding to programming