Displaying the log output definition details – Allied Telesis AT-S63 User Manual
Page 282

Chapter 13: Event Logs and Syslog Servers
282
Section II: Advanced Operations
7. After making changes, type R until you return to the Main Menu. Then
type S to select Save Configuration Changes.
Displaying the
Log Output
Definition Details
To view the settings of a log output definition you have already created,
perform the following procedure:
1. From the Main Menu, type 5 to select System Administration.
The System Administration menu is shown in Figure 4 on page 54.
2. From the System Administration menu, type 8 to select Event Log.
The Event Log menu is shown in Figure 77 on page 263.
3. From the Event Log menu, type L to select Configure Log Outputs.
The Configure Log Outputs menu is shown in Figure 81 on page 275.
4. From the Configure Log Outputs menu, type 4 to select View Log
Output Details.
The following prompt is displayed:
Enter output ID to view [0 to 20] ->
5. Enter the number of the log output that you want to view.
The Syslog Output Configuration menu for the selected output is
displayed, as shown in Figure 84.
Figure 84. Syslog Output Configuration Menu for Selected Output ID
To modify the log output configuration, refer to “Modifying a Log
Output” on page 280.
6. Return to the Main Menu.
Allied Telesyn Ethernet Switch AT-94xx - AT-S63
Marketing
User: Manager
11:20:02 02-Mar-2005
Syslog Output Configuration
1 - Output ID ................ 3
2 - Server IP Address ........ 149.35.87.45
3 - Message Generation ....... Enabled
4 - Message Format ........... Extended
5 - Facility Level ........... DEFAULT
6 - Event Severity ........... E,W,I
7 - Event Module ............. All
R - Return to Previous Menu
Enter your selection?