Management area capacity of an open-systems volume, Capacity of a slot – HP XP P9500 Storage User Manual
Page 49
where
•
the value enclosed in ceil( ) must be rounded up to the nearest whole number.
•
calculated-management-area-capacity
depends on volume emulation types and
RAID levels (see
“Management area capacity of an open-systems volume” (page 49)
).
To calculate the entire capacity of a CV if the data protection level is set to the Enhanced mode
on the SATA drive:
ceil(entire-capacity-of-a-CV(slots) +
calculated-management-area-capacity)
To convert the resulting entire capacity into blocks:
calculated-entire-capacity-of-a-CV(slots) *
capacity-of-a-slot * 2
where
•
calculated-entire-capacity-of-a-CV(slots)
means the entire capacity of a CV
if the data protection level is set to the Enhanced mode on the SATA drive.
Management area capacity of an open-systems volume
Management area capacity (KB)
Emulation type
None
OPEN-V
5,760
OPEN-3
19,440
OPEN-8
19,440
OPEN-9
13,680
OPEN-E
Boundary values for RAID levels other than Enhanced mode on SATA drives
Boundary values of external volumes are always one kilobyte, regardless of RAID levels.
Boundary value (KB)
Emulation type
RAID 6 (6D+2P)
RAID 5 (7D+1P)
RAID 5 (3D+1P)
RAID 1 (2D+2D)
2,304
2,688
1,152
768
Other than OPEN-V
3,072
3,584
1,536
1,024
OPEN-V
Boundary values for RAID levels (enhanced data protection level on SATA drives)
A SATA drive supports the OPEN-V emulation type for an open system.
Boundary value (KB)
Emulation type
RAID 6 (6D+2P)
RAID 5 (7D+1P)
RAID 5 (3D+1P)
RAID 1 (2D+2D)
24,576
28,672
6,144
2,048
OPEN-V
Capacity of a slot
Capacity (KB) of a slot
Emulation type
48
Other than OPEN-V
256
OPEN-V
VLL size calculations
49