HP XP P9500 Storage User Manual
Page 169
Troubleshooting provisioning while using RAID Manager
If an error occurs while operating Data Retention on theor Thin Provisioning while using RAID
Manager, you might identify the cause of the error by referring to the log displayedappearing on
the RAID Manager window or the RAID Manager operation log file.The RAID Manager operation
log file is stored in the following directory by default.
The RAID Manager operation log file is stored in the following directory.
/HORCM/log*/curlog/horcmlog_HOST/horcm.log
where
•
* is the instance number.
•
HOST is the host name.
The following is an example of a log entry in the RAID Manager window.
For more troubleshooting information, see:
•
“Errors when operating RAID Manager (Thin Provisioning, SSB1:0xb96b) ” (page 169)
•
“Errors when operating RAID Manager (Data Retention, SSB1:B9BF/B9BD)” (page 170)
Errors when operating RAID Manager (Thin Provisioning, SSB1:0xb96b)
Solutions
Error Contents
Error Code (SSB2)
Ask the HP Technical Support to solve the
problem.
Error occurred when increasing THP V-VOL
capacity operation.
0xb900/ 0xb901/
0xaf28
Increase the THP V-VOL capacity after finishing
operations on your storage system, such as the
The operation was rejected because the
configuration was being changed by SVP or
0xb902
Virtual LUN operation or a maintenance
Remote Web Console, or because the THP
operation. See Caution in
increasing THP V-VOL capacity” (page 66)
.
V-VOL capacity was going to be increased by
another instance of the RAID Manager.
Increase the THP V-VOL capacity after the
specified volume is placed online with the OS
which supports EAV.
The operation was rejected because the
specified volume is placed online with the OS
which does not support EAV (Extended Address
Volume).
0xaf22
Specify a capacity so that the pool reservation
rate will not be exceeded.
The operation was rejected because the total
THP V-VOL capacity exceeded the pool
0xaf24
reservation rate after the capacity was
increased.
Specify a capacity so that the maximum number
of cache management devices will not be
exceeded.
The operation was rejected because of lack of
cache management devices due to increased
capacity.
0xaf26
Makes sure that the volume is a THP V-VOL.
Because the specified volume was not a THP
V-VOL, the operation was rejected.
0xaf29
To increase capacity, specify the correct
capacity that does not exceed the value
Because the specified capacities are invalid or
exceeded the value immediately below LDEV
0xaf2a
immediately below LDEV Capacity in the Expand
Capacity in the Expand Virtual Volumes
window, the operation was rejected.
Virtual Volumes window. See the conditions for
increasing THP V-VOL capacity in
for increasing THP V-VOL capacity” (page 66)
.
Re-execute the operation after a brief interval.
Because the specified volume operation was not
finished, the operation was rejected.
0xaf2b
Troubleshooting provisioning while using RAID Manager