HP XP P9500 Storage User Manual
Page 260
Description
Item
Nickname and identifier of the pool.
Pool Name (ID)
RAID level of the pool.
RAID Level
Mixed indicates multiple RAID levels exist in a pool.
Pool capacity.
Capacity
How the pool is being used.
Pool Type
•
For Thin Provisioning or Smart Tiers: THP appears.
•
For Snapshot: Snapshot appears.
Drive type and RPM of the pool. Mixed indicates the drive types or RPMs in the
pool are mixed.
Drive Type/RPM
User-defined pool threshold values, in %.
User-Defined threshold (%)
•
Warning: The value defined for the Warning Threshold.
•
Depletion: The value defined for the Depletion Threshold.
For a Snapshot pool, a hyphen (-) appears for Depletion.
Subscription limit, in %, of the pool.
Subscription Limit (%)
The subscription limit is the ratio (%) of the V-VOL capacity that can be configured
to the total capacity of the pool volume. You cannot configure the V-VOL capacity
to exceed the subscription limit. For example, if the pool volume capacity is 100
GB and the subscription limit is 150%, you can configure up to 150 GB of the
capacity of V-VOL.
For Snapshot pool, a hyphen (-) appears.
Number of the pool-VOLs in the pool.
Number of Pool VOLs
260 Thin Provisioning and Smart Tiers GUI reference
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- Linear Tape File System Software (28 pages)
- Linear Tape File System Software (25 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- 2000fc Modular Smart Array (150 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (127 pages)
- Software de HP StoreVirtual VSA (85 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- 200 Storage Virtualization System (176 pages)
- XP Array Manager Software (101 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (93 pages)
- Data Protector Express Basic-Software (83 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- ProLiant High Availability Storage Server (72 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)