Performance monitor – HP XP P9500 Storage User Manual
Page 37

Condition
Operation name
When you select the Apply same settings to the HBA WWN of all ports check box,
all the host groups where the specified HBA WWNs are registered must be assigned
to the Storage Administrator group permitted to manage them.
When you select the Remove hosts from all host groups containing the hosts in the
storage system check box, all the host groups where the HBA WWNs displayed
Remove Hosts
in the Selected Hosts table are registered must be assigned to the Storage
Administrator group permitted to manage them.
The specified ports must be assigned to the Storage Administrator group permitted
to manage them.
Edit Ports
The specified host groups and all the LDEVs where the paths are set to the host
groups must be assigned to the Storage Administrator group permitted to manage
them.
Create Alternative LUN Paths
The specified host groups and the LDEVs where the paths are set must be assigned
to the Storage Administrator group permitted to manage them.
Copy LUN Paths
LDEVs where the specified paths are set must be assigned to the Storage
Administrator group permitted to manage them.
Edit Command Devices
The specified LDEV must be assigned to the Storage Administrator group permitted
to manage them.
Edit UUIDs
The specified LDEV must be assigned to the Storage Administrator group permitted
to manage them.
Delete UUIDs
When you open the Create Host Groups window by specifying host groups, the
specified host groups must be assigned to the Storage Administrator group permitted
to manage them.
Create Host Groups
The specified host groups and all the LDEVs where the paths are set to the host
groups must be assigned to the Storage Administrator group permitted to manage
them.
Delete Host Groups
Performance Monitor
The following table provides information about specific Performance Monitor conditions that must
be observed when using Resource Partition.
Condition
Operation name
The specified ports must be assigned to the Storage Administrator group permitted
to manage them.
Add to Ports
The specified ports must be assigned to the Storage Administrator group permitted
to manage them.
Add New Monitored WWNs
The specified ports must be assigned to the Storage Administrator group permitted
to manage them.
Edit WWN
Using Resource Partition and other HP P9500 products
37