Business copy, Continuous access synchronous, Business copy continuous access synchronous – HP XP P9500 Storage User Manual
Page 38
Business Copy
The following table provides information about specific Business Copy conditions that must be
observed when using Resource Partition.
Condition
Operation name
Both P-VOLs and S-VOLs must be assigned to the Storage Administrator group
permitted to manage them.
Create pairs
Split pairs
Suspend pairs
Resynchronize pairs
Release pairs
The specified LDEVs must be assigned to the Storage Administrator group permitted
to manage them.
Set reserve attributes
Remove reserve attributes
Continuous Access Synchronous
The following table provides information about specific Continuous Access Synchronous conditions
that must be observed when using Resource Partition.
Condition
Operation name
P-VOLs must be assigned to the Storage Administrator group permitted to manage
them.
Create pairs
Initiator ports for the logical paths that are configured between P-VOLs and RCU
must be assigned to the Storage Administrator group permitted to manage them.
P-VOLs must be assigned to the Storage Administrator group permitted to manage
them.
Change pair options
The specified P-VOLs or S-VOLs must be assigned to the Storage Administrator
group permitted to manage them.
Split pairs
P-VOLs must be assigned to the Storage Administrator group permitted to manage
them.
Resynchronize pairs
The specified P-VOLs or S-VOLs must be assigned to the Storage Administrator
group permitted to manage them.
Release pairs
When you specify P-VOLs, initiator ports for the logical paths that are configured
between P-VOLs and RCU must be assigned to the Storage Administrator group
permitted to manage them.
The specified ports must be assigned to the Storage Administrator group permitted
to manage them.
Define port attributes
The specified initiator ports must be assigned to the Storage Administrator group
permitted to manage them.
Add RCU
Initiator ports of logical paths to the specified RCUs must be assigned to the Storage
Administrator group permitted to manage them.
Delete RCU
Change RCU option
The specified initiator ports must be assigned to the Storage Administrator group
permitted to manage them.
Add logical paths
Delete logical paths
38