Initializing iscsi target 0 (zero), Changing a host bus adapter's wwn and nickname, Change wwn & nickname dialog box – HP StorageWorks XP10000 Disk Array User Manual

Page 97

background image

Initializing iSCSI target 0 (zero)

If you follow the procedure below, iSCSI target 0 (zero) is set to its initial state. This procedure removes

all LU paths related to iSCSI target 0. This procedure also changes iSCSI target 0's host mode to

Standard and initializes the iSCSI target name. After this procedure, the iSCSI target's name changes to

its default name.

1.

Start LUN Manager. The LUN Manager pane (

Figure 15

) appears.

2.

In the tree, right-click iSCSI target 0, which is preceded by 00, and select Clear Host Group. A

confirmation message appears.

3.

Click YES.
iSCSI target 0's host mode and host group name are changed in the tree. iSCSI names are also

removed from iSCSI target 0.
LU paths are removed from the table on the right of the tree. LUNs corresponding to removed LU

paths appear in blue.

4.

Click Apply. A confirmation message appears.

5.

Click OK. Changes are applied to the array.

Changing a host bus adapter's WWN and nickname

In Fibre Channel environments, you can identify host bus adapters by WWNs or nicknames.

1.

Start LUN Manager. The LUN Manager pane (

Figure 14

) appears.

2.

In the tree, double-click the Fibre folder. A list of Fibre Channel ports appears.

3.

In the tree, double-click the Fibre Channel port to which the host bus adapter is connected.

4.

In the tree, right-click a host bus adapter (

), and select Change WWN & Nickname. The Change

WWN & Nickname dialog box appears.

Figure 51 Change WWN & Nickname dialog box

5.

To change the WWN, enter a new WWN or select another WWN from the WWN list.
To change the nickname, enter a new nickname In the Nickname box.

6.

If necessary, select Apply this change to other ports, too.
If this check box is selected, the change in the pane also affects other ports. For example, suppose

that the same host bus adapter (that is, the same WWN) is located below ports CL1-A and CL2-A in

the tree. If you select the host bus adapter (or WWN) from below one of the ports and change the

nickname to hba1, the host bus adapter below the other port is also renamed to hba1.

HP StorageWorks LUN Configuration and Security Manager XP user guide for the

XP12000/XP10000/SVS200

97