Ping pane, Ping status pane – HP StorageWorks XP10000 Disk Array User Manual
Page 114
Figure 61 Ping pane
3.
From the From (Subsystem Port) list, select an iSCSI port.
4.
In To (IP Address) box, enter the host's IP address.
5.
Click OK.
A ping command is issued from the iSCSI port to the host five times. After the ping command is
issued five times, the Ping Status pane appears and displays the results of the first to fifth attempts at
issuing the ping command. The results appear in the order attempts were made.
Figure 62 Ping Status pane
6.
On the Ping Status pane, check the results of the ping command.
• If the host responded to the ping command, the Status column displays Success.
• If the host did not respond to the ping command, the Status column displays Error.
• The Success Rate field displays the ping command's success rate. If the host responds to each
of the five ping attempts, the success rate is 100 percent. If the host responds three times out
of five ping attempts, the success rate is 60 percent.
7.
Click OK.
8.
To issue a ping command, return to step 3.
Otherwise, click Cancel.
TIP:
You can issue a ping command from an iSCSI port to an iSNS server. To verify connectivity
between an iSNS server and the array, issue a ping command to the iSNS server. If the
iSNS responds to the ping command, the iSNS server and array can communicate with
each other.
114
LUN Manager operations