beautypg.com

Deleting host groups, Change iscsi target pane, Change iscsi target pane (option selected) – HP StorageWorks XP10000 Disk Array User Manual

Page 95

background image

Figure 49 Change iSCSI Target pane

3.

To change the iSCSI target's name, enter a new name in the Target name box.
To change the alias, enter a new alias in the Target alias box. iSCSI target aliases can include

letters, numbers, periods (.), hyphens (-), and colons (:); but cannot include double-byte characters.

iSCSI target aliases are case-sensitive. An iSCSI target alias can consist of up to 32 characters
To change the host mode (see

Table 16

), select the new host mode from the Host Mode list.

4.

If necessary, click Option, and select the host mode options. For more information about host

mode options, see

Table 17

.

Figure 50 Change iSCSI Target pane (Option selected)

NOTE:

After you click Option, the pane expands to display a list of host mode options. The No.

column indicates option numbers. Select the check box of the option you want to specify.

5.

Click OK. Changes are indicated in blue in the tree.

6.

Click Apply. A confirmation message appears.

7.

Click OK. Changes to the iSCSI target name and host mode are applied to the array.

Deleting host groups

NOTE:

You cannot perform this operation on host groups for NAS ports.

You cannot delete host group 0 (zero). To remove all WWNs and LU paths from host group 0, you

must initialize host group 0 (for more information, see

Initializing host group 0 (zero)

).

HP StorageWorks LUN Configuration and Security Manager XP user guide for the

XP12000/XP10000/SVS200

95