HP StorageWorks XP10000 Disk Array User Manual
Page 89
a. In the iSCSI name table, select the port to which the host is connected from the Port list.
b. In the iSCSI name list, select the host bus adapter. From the tree, select an iSCSI target, and
click Add iSCSI name.
Figure 41 Add New iSCSI name pane (registering a host that was previously
connected to the array)
• In this list, only iSCSI names of hosts that issued login commands to ports appear.
Regardless of the sessions (Discovery or Normal) or results (Accept or Reject), up to
64 iSCSI names of hosts that recently issued login commands to each port appear.
However, if a host issues more than one instance of the login command to the same
port, the host's iSCSI name appears only once in the list.
To register iSCSI names using this list and register multiple hosts collectively to one port, you
must register the iSCSI names to the port before the iSCSI names are deleted from this list. If
the iSCSI names are deleted and you want to redisplay the iSCSI names in this list, you must
reissue the login command from the hosts. In this case, you should operate the hosts that
need to log in, and should not add unnecessary iSCSI names to this list.
• If you are using Windows, you can drag the host bus adapter from the iSCSI name
table to the iSCSI target in the tree. To drag two or more host bus adapters, see
the HP StorageWorks Command View XP user guide for XP Disk Arrays or the
HP StorageWorks XP Remote Web Console user guide for XP12000/XP10000/SVS200
for instructions.
c. To assign a nickname to the host bus adapter, enter the nickname in the Nickname box, and
click OK.
NOTE:
If you select two or more host bus adapters, Add New iSCSI name panes (
)
appear one after another to let you assign nicknames to the selected HBAs. If you do
not need to assign nicknames to HBAs, you can select The remaining iSCSI names do
not need names, and click OK. If you select this option, the Add New iSCSI name
pane (
) no longer appears to prompt you to assign nicknames.
3.
If the host has never been connected via a cable to any port in the array, take the following steps:
a. In the tree, right-click the iSCSI target, and select Add New iSCSI name. The Add New iSCSI
name pane appears.
HP StorageWorks LUN Configuration and Security Manager XP user guide for the
XP12000/XP10000/SVS200
89