Associating host groups, Or iscsi targets to logical volumes, Associating host groups or – HP StorageWorks XP10000 Disk Array User Manual

Page 90: Iscsi targets to logical volumes

background image

Figure 42 Add New iSCSI name pane (registering a host that has never been

connected to the array)

b. In the iSCSI name list, select the host bus adapter. If the list does not include the host bus

adapter, enter the iSCSI name in the iSCSI name box.

c. If necessary, enter a nickname for the host bus adapter.
d. Click OK. The specified iSCSI name and nickname appear below the selected iSCSI target.

4.

Click Apply. A confirmation message appears.

5.

Click OK. Settings are applied to the array, and the specified host is registered in the iSCSI target.

Associating host groups or iSCSI targets to logical volumes

Use LUN Manager to define LU paths by associating host groups or iSCSI targets to logical volumes. For

example, if you associate a host group or iSCSI target consisting of three hosts with logical volumes, LU

paths are defined between the three hosts and the logical volumes.

1.

Start LUN Manager. The LUN Manager pane (

Figure 14

or

Figure 15

) appears.

2.

In the tree, select a host group or iSCSI target.

NOTE:

If you are configuring a NAS environment, you must select the User host group.

3.

In the CU list above the LDEV table, select a CU number. The LDEV table shows LDEVs in the

specified CU image.

4.

In the LDEV table, select a logical volume. In the LU Path table, select LUNs indicated by the

icon

(this icon indicates a LUN to which no LU path is defined). Click Add LU Path.
A message appears displaying information about LU paths to be defined.

NOTE:

• If you are using Windows, you can drag a logical volume from the LDEV table to

a LUN (

) in the LU Path tree. To drag more than one logical volume, see the

HP

StorageWorks Command View XP user guide for XP Disk Arrays

or the

HP StorageWorks

XP Remote Web Console user guide for XP12000/XP10000/SVS200

for instructions.

• When you use the LU Path tree, you can use the CU list to switch between CU images.

90

LUN Manager operations