Host mode options – HP StorageWorks XP10000 Disk Array User Manual
Page 84
Table 17 Host mode options
No.
Host mode option
When to select this option
2
VERITAS Database
Edition/Advanced
Cluster
When VERITAS Database Edition/Advanced Cluster for Real
Application Clusters or VERITAS Cluster Server 4.0 (I/O fencing
function) is used
6
TPRLO
When all the following conditions are satisfied:
•
Host mode 0C Windows or 2C Windows Extension is used
•
Emulex host bus adapters are used
•
Mini-port drivers are used
•
TPRLO=2 is specified for the host bus adapter's mini-port driver
parameter
7
Automatic recognition
function of LUN
When all the following conditions are satisfied:
•
Host mode 00 Standard or 09 Solaris is used
•
SUN StorEdge SAN Foundation Software Version 4.2 or later is used
•
You want to automate recognition of increase and decrease of
devices when a genuine SUN HBA is connected
12
Undisplay function of
ghost LUN
When all the following conditions are satisfied:
•
Host mode 03 HP is used
•
You want to suppress creation of device files for devices to which
paths are not defined
13
SIM report at link failure
When you want to be informed by service information message (SIM)
that the number of link failures detected between ports exceeds the
threshold.
14
HP TruCluster with
Continuous Access XP
function
When all the following conditions are satisfied:
•
Host mode 07 Tru64 is used
•
You want to use TruCluster to set a cluster to the Continuous Access
XP P-VOL and S-VOL, respectively
19
VMware
When registering VMware server hosts in the host group, make sure
to select this option.
24
2TB or Larger LUN
Support
When one of the following operating systems is installed on the hosts,
and the hosts are to access LUs larger than 2 TB:
•
AIX 5.2 TL08 or later
•
AIX 5.3 TL04 or later
•
Windows Server 2003 SP1 or later
•
Red Hat Enterprise Linux AS 4 Update 1 or later
CAUTION:
Other operating systems do not support LUs larger than 2 TB. If
other operating systems are used by hosts, make sure that LUs
are not larger than 2 TB.
CAUTION:
For information about the maximum LU capacity supported by
your operating system, contact the manufacturer of your operating
system.
Creating iSCSI targets (when configuring iSCSI environments)
You can connect multiple server hosts on different platforms to one port on the array. When configuring
the system, you must group server hosts connected to the array by iSCSI targets. For example, if HP-UX
and Windows hosts are connected to a port, you must create one iSCSI target for HP-UX hosts and
another iSCSI target for Windows hosts. Next, you must register HP-UX hosts to the corresponding iSCSI
target and register Windows hosts to the other iSCSI target.
84
LUN Manager operations