beautypg.com

3 specifications, Fluid conditions, Piping conditions – Dwyer PUX User Manual

Page 99: Accuracy converter, Bulletin f-68

background image

15 - 8

15.3 Specifications

Fluid conditions

Measured fluid:

Homogeneous liquids (water, sea water, oil or fluid of unknown sound velocity)
capable of ultrasonic wave propagation

Turbidity of fluid:

10000 deg. (mg/L) or less

State of flow:

Axis-symmetric flow in pipe filled with fluid

Fluid temperature:

Small diameter sensor, –

40 to +100

°

C

Small sensor, [Standard] –

40 to +100

°

C

Large sensor, –

40 to +80

°

C

High-temperature sensor, –

40 to +200

°

C

Velocity range:

–32 to 0 to +32m/s

Piping conditions

Pipe material:

Steel, stainless steel, cast iron, vinyl-chloride, FRP, asbestos, aluminum, acrylic,
etc.

Pipe size:

Small diameter sensor,

φ

13 to

φ

100

Small sensor,

φ

50 to

φ

400

Large sensor,

φ

200 to

φ

6000

High-temperature sensor,

φ

50 to

φ

400

Lining material:

None, tar epoxy, mortar, rubber or material of known sound velocity

Straight pipe length: Upstream side, 10D or more

Downstream side, 5D or more (D: inner pipe diameter)
Refer to Japan Electric Measuring Instruments Manufactures’ Association’s stan-
dard JEMIS-032 for details.

Accuracy

Converter

Power supply:

Built-in battery or power adaptor

Built-in battery:

Special type Ni-MH battery
Continuous operation time, about 5 hours (without printer, back light OFF, with-
out current output, transmission voltage setting

×

1)

Recharging time, about 2 hours (power adaptor used)

Power adaptor:

Special type power adaptor 90 to 264V AC, 47 to 63Hz or 10 to 30V DC

Power consumption: 12W or less

LCD display:

Full dot graphic display
240 x 320 dot (with back light)

LED display:

DC IN (green), FAST CHARGE (red)

Key pad:

10 keys (ON, OFF,

,

,

,

, ESC, ENT, LIGHT, PRINT)

Power failure backup: Memory backup with lithium battery (effective term, 5 years)

Response time:

1s or less

Output signal:

4 to 20mA DC, 1 point (load resistance, 0 to 1k

)

Input signal:

4 to 20mA DC (not isolated), 1 point

Serial communication: RS-232C (not isolated), 1 point

Transmission speed: Max. 9600 bps
Transmission distance: Max. 15m

Printer (option):

To be mounted on top of converter
Thermal serial dot printing (8 x 256 dot)

Ambient temperature: –10 to +55

°

C (without printer)

–10 to +45

°

C (with printer)

Ambient humidity:

90% RH or less

Type of enclosure:

Dust-proof type (IP50 or equivalent)

Pipe size

φ

13 to

φ

50 or less

φ

50 to

φ

300 or less

φ

300 to

φ

6000

Flow velocity

2 to 32 m/s

0 to 2 m/s

2 to 32 m/s

0 to 2 m/s

1 to 32 m/s

0 to 1 m/s

Accuracy

1.5% of rate

0.03m/s

1.0% of rate

0.02m/s

1.0% of rate

0.01m/s

(Note) Reference conditions are

based on JEMIS-032.

BULLETIN F-68