Caution, Bulletin f-68, H] select “flow rate” and press the – Dwyer PUX User Manual
Page 50: Key. move the cursor to [m, H], select “on” and press the, Key. to close the screen, press the, Key. y select “start date/time” and press the
9 - 9
t
Select the kind of data to be logged.
One or more data can be selected.
Select the kind of data by the
or
key, turn it ON and press the
ENT
key for starting logging.
•
Move the cursor to any of “FLOW RATE”, “VELOCITY”, “+TOTAL”, “-TOTAL” and
“ANALOG IN”. Press the
ENT
key, and the “ON/OFF SELECTION” screen is displayed.
•
Select “FLOW RATE” and press the
ENT
key, and then the “UNIT” selection screen is displayed.
Move the cursor to any of the flow rates units and press the
ENT
key. Set either ON or OFF.
•
To select “VELOCITY”, “+TOTAL”, “-TOTAL” and “ANALOG IN”, move the cursor to any of
them and press the
ENT
key. Then select ON or OFF.
[Example] To save flow rate [m
3
/h]
Select “FLOW RATE” and press the
ENT
key. Move the cursor to [m
3
/h], select “ON” and press the
ENT
key. To close the screen, press the
ENT
key.
y
Select “START DATE/TIME” and press the
ENT
key, so the setting can be accomplished.
u
Select “END DATE/TIME” and press the
ENT
key, so the setting can be accomplished.
i
Select “SAMPLE INTERVAL” and press the
ENT
key, so the setting can be accomplished.
Pressing the
or
key moves the digit, and
enter numeric values by pressing the
or
key.
After entry, press the
ESC
key.
CAUTION
Set the timer at a few minutes earlier than
present time, or the setting will be performed
at one year later.
LOGGER
START DATE / TIME 10-30 05 : 17
END DATE / TIME 10-30 05 : 17
SAMPLE INTERVAL
00 : 00: 01
+TOTAL
—TOTAL
LOGGER NAME
MODE
SETUP
REMAIN
255 BLOCK
VELOCITY
FLOW RATE
OFF
Mm3 / d
unit
m3 / h
m3 / min
m3 / s
ML / d
L / h
L / min
L / S
BBL / s
BBL / min
BBL / h
MBBL / d
m3 / h
OFF
ON
VELOCITY
OFF
—TOTAL
OFF
ON
ANALOG IN
ANALOG IN
OFF
ON
+TOTAL
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ANALOG IN
OFF
OFF
LOGGER
START DATE / TIME
10-30 05 : 17
END DATE / TIME 10-30 05 : 17
SAMPLE INTERVAL 00 : 00: 01
+TOTAL
—TOTAL
LOGGER NAME
MODE
SETUP
REMAIN
255 BLOCK
VELOCITY
FLOW RATE
TEST 123
OFF
OFF
ANALOG IN
OFF
OFF
ON
ON
First, the present time is displayed
Example)
When setting the start time at
15: 09 on June 27:
|START DATE/TIME: 06-27 15:09|
Example)
When setting the sample interval at
01: 20 : 00:
|SAMPLE INTERVAL: 01: 20: 00|
Note) For FLOW RATE, one or
more units are selectable.
Select the units of flow rate
on the UNIT screen.
Registered name is
displayed.
TEST 123
BULLETIN F-68