2 setting of analog output, Dc in, Dc power supply – Dwyer PUX User Manual

Page 61: Caution, 2) range unit: when setting measurement unit, Bulletin f-68, Operation

background image

9 - 20

9.4.2 Setting of analog output

(1) DISPLAY: when displaying present measured instantaneous flow

[Operation]

q

Press the

or

key on the “ANALOG IN/

OUT” page and select “DISPLAY” from
“OUTPUT”.

Press the

ENT

key to display presently-

measured instantaneous flow.

Output = instantaneous flow

×

100/range

(2) RANGE UNIT: when setting measurement unit

q

Press the

or

key on the “ANALOG IN/

OUT” page and select “RANGE UNIT” from
“OUTPUT”.

Press the

ENT

key, and the “UNIT” screen is

d i s p l a y e d , e n a b l i n g y o u t o s e l e c t t h e
measurement unit.

w

Select the measurement unit by the

or

key

and press the

ENT

key.

(3) OUTPUT RANGE: when setting the range for output current

q

Press the

or

key on the “ANALOG IN/

OUT” page and select “OUTPUT RANGE”
from “OUTPUT”.

Press the

ENT

key, and you are ready to adjust

output range.

w

Move the digit by the

or

key and enter

numeric values by pressing the

or

key.

After entry, press the

ENT

key to set the range.

Example)

In case of the range of 0 to 80 L/s at 4 to 20 mA

8.000 E1 (8.000

×

10)

Index is settable in range from
-9 to +9

Mantissa

Index

ANALOG IN /OUT

ANALOG IN /OUT

INPUT

ANALOG

0 . 0 0 0 E 0

DISPLAY

INPUT RANGE

ADJUST

OUTPUT

RANGE UNIT

OUTPUT RANGE

OUTPUT MODE

BURN-OUT

ADJUST

m/s

HOLD

1 . 0 0 0 E 0

0 . 8 - 4 - 2 0 m A

DISPLAY

DISPLAY

OUTPUT CHECK

0.00%

ESC

DISPLAY

ANALOG IN / OUT

INPUT

ANALOG

0 . 0 0 0 E 0

DISPLAY

INPUT RANGE

OUTPUT

DISPLAY

OUTPUT RANGE

OUTPUT MODE

BURN-OUT

ADJUST

m/s

HOLD

1 . 0 0 0 E 0

0 . 8 - 4 - 2 0 m A

ESC

ADJUST

ANALOG IN / OUT

INPUT

ANALOG

0 . 0 0 0 E 0

DISPLAY

INPUT RANGE

OUTPUT

DISPLAY

RANGE UNIT

OUTPUT MODE

BURN-OUT

ADJUST

L/s

HOLD

1 . 0 0 0 E 0

0 . 8 - 4 - 2 0 m A

ADJUST

m 3 / h

UNIT

UNIT

m 3 / m

m 3 / s

M I / d

l / h

l / m

l / s

M m 3 / d

B B L / s
B B L / m
B B L / h

m / s

m / s

M B B L / d

OUTPUT RANGE

RANGE UNIT

The “OUTPUT RANGE” initial value is 0.000E0.
Unless “OUTPUT RANGE” is set, “DISPLAY”
is 0.00%.

CAUTION

Set RANGE so that flow rate to be measured exceeds 1.2 times its maximum value.

If measured value exceeds the set value, the status display on the MEASURE screen turns “ANALOG
OUTPUT ERROR”.

Unless analog output is used, set the range at 0, and “ANALOG OUTPUT ERROR” is not displayed.

CAUTION

BULLETIN F-68