beautypg.com

4 to set printing intervals, 5 to set graph scale in graph mode, Bulletin f-68 – Dwyer PUX User Manual

Page 72

background image

9 - 31

9.5.4 To set printing intervals

q

Press the

or

key on the PRINT page,

select “SAMPLING PERIOD” and press the

ENT

key. The SAMPLING PERIOD screen is

displayed.

w

Move the digit by pressing the

or

key, and

enter a numeric value by pressing the

or

key. Press the

ENT

key and set the sampling

period.

Setting

In the TEXT mode:

00 : 00
Hour: Minute

In the GRAPH mode:

00 : 00 : 00
Hour: Minute: Second

Example) When printing data in a graph every 20

minutes, set the print period to “00 : 20 : 00”.

9.5.5 To set graph scale in GRAPH mode

[This setting should be done only when the “GRAPH” mode is set.]

q

Press the

or

key on the PRINT page,

select “LEFT” from “SCALE SET” and press
the

ENT

key. The screen is displayed, enabling

you to set measured values at LEFT.

w

Move the digit by the

or

key and enter a

numeric value by the

or

key.

Press the

ENT

key to set measured value at

LEFT.

e

Press the

key to set “RIGHT”.

r

Set RIGHT in the same manner as in “LEFT”.

t

Press the

ENT

key to return to the previous

screen.

PRINTER

MODE

GRAPH

UNIT

L / m i n

TIMER MODE

MANUAL

PRINT OUT

+ TOTAL
— TOTAL

OFF
OFF

SAMPLE PERIOD

0 0 : 0 0 : 0 1

SCALE SET

LEFT

RIGHT

0 . 0 0 0 E 0
1 . 0 0 0 E 0

PRINTER

MODE

TEXT

UNIT

FLOW RATE
VELOCITY
+TOTAL
—TOTAL

OFF
OFF
OFF

TIMER MODE

TIMER

0 0 : 0 1

PRINT OUT

ANALOG IN

OFF

SAMPLING PERIOD

BULLETIN F-68