9 selection of sensor mounting method, Selection of sensor mounting method - 10, Bulletin f-68 – Dwyer PUX User Manual
Page 27: V method z method, Remarks
6 - 10
6.9
Selection of sensor mounting method
Mounting methods available for the sensor are V method
and Z method as illustrated.
To select the mounting method;
Press the
key to invert the “SENSOR MOUNTING”.
Press the
ENT
key. The “SENSOR MOUNTING” screen
will appear.
Select either V or Z method using the
or
key.
V method
Z method
ENT
ENT
SITE SETUP
SITE SETUP
SITE SETUP
PIPE PARAMETER
PIPE PARAMETER
V
SITE NAME
OUTER DIAMETER
PIPE MATERIAL
WALL THICKNESS
LINING MATERIAL
KIND OF FLUID
SENSOR MOUNTING
SENSOR MOUNTING
PSX2 B
SENSOR TYPE
LINING THICKNESS
WATER
4 TIMES
TRANS. VOLTAGE
SITE SETUP
SITE SETUP
SITE SETUP
PIPE PARAMETER
PIPE PARAMETER
SITE NAME
OUTER DIAMETER
PIPE MATERIAL
PIPE MATERIAL
WALL THICKNESS
LINING MATERIAL
KIND OF FLUID
SENSOR MOUNTING
SENSOR TYPE
LINING THICKNESS
TRANS. VOLTAGE
1.25 m m
MORTAR
1.25mm
CAST IRON
318.50 m m
PIPE NO.1
SENSOR MOUNTING
SENSOR MOUNTING
Z
V
Select the V method generally. Use the Z method in
the following cases:
• Ample space is not provided.
• High turbidity
• Weak receiving waveform
• Thick scale is deposited on the pipe internal
surface.
Remarks
BULLETIN F-68