Power cord, 2 setting of logging function (data logger page), Bulletin f-68 – Dwyer PUX User Manual
Page 48: How to view data logger
9 - 7
9.2
Setting of logging function (data logger page)
This function allows you to save measured values to the memory of the main unit, call the measured data
saved to the memory after measurement is completed, display, and produce output of them on a printer.
The data logger can contain up to 40,000 measured data.
How to view data logger
95-06-27 15:01
LOGGER
LOGGER
MODE
No
SETUP
REMAIN
LOG NAME
1
2
3
4
5
6
7
8
9
10
120 BLOCK
DATA
F
low Site
.
**
EMPTY
**
**
EMPTY
**
**
EMPTY
**
**
EMPTY
**
**
EMPTY
**
**
EMPTY
**
**
EMPTY
**
**
EMPTY
**
Indicates the number of
remaining memory blocks.
One block consists of 156 data.
No. of all blocks: 256
Calculation of remaining amount of memory
In case of 120 blocks
120 blocks
×
156 data = 18720 data
If the setting contents exceed the remaining
amount of memory, the data logger is not
available.
The message appears as shown below.
Sets operation.
Indicates the
storage status.
**EMPTY** indicates
that data is not stored.
Up to 20 boxes can be viewed
by using the cursor.
GUIDANCE
ENTER KEY
OUT OF MEMORY !
Set the setting contents within the
range of the remaining amount of memory.
When the data is already saved, the check
mark ( ) is placed here.
w
w
w
w
w
To set reset data
To reset the integration reset data, move the
c u r s o r t o “ R E S E T D A T A ” a n d p r e s s
the
ENT
key. Select numerical values by
pressing the
,
,
,
key and press
the
ENT
key.
[Settable rage: 0000000 to 9999999]
Resetting actual integral values should be
performed on the “MEASURE” screen. (See
page 8-1).
e
e
e
e
e
To change integration unit
To set integration units, move the cursor to
“UNIT” and press the
ENT
key. The Unit
screen appears, prompting you to select units of
integration. Select units by pressing the
or
key and press the
ENT
key.
TOTALIZE
SITE SETUP
RESET DATA
MODE
OFF
0
UNIT
m L
TOTALIZE
SITE SETUP
RESET DATA
MODE
OFF
0
UNIT
m l
ESC
SITE SETUP
TOTALIZE
UNIT
K m 3
m
3
m B B L
M m 3
K B B L
B B L
L
m L
BULLETIN F-68