beautypg.com

Specifications for serial transmission (rs-232c), 12 - 1 (1) general specifications, 2) interface specifications – Dwyer PUX User Manual

Page 86: 3) composition, Bulletin f-68

background image

12 - 1

(1) General specifications

Communication system : Half-duplex
Synchronizing system

: Start-stop synchronizing

Transmission speed

: 300 / 600 / 1200 / 2400 / 4800 / 9600 bps (selectable)

Parity

: Even/odd number / None (selectable)

Data length

: 8 bits

Stop bit

: 1 bit / 2 bits (selectable)

Data code

: ASCII

Insulation

: Non-insulation between transmission line and converter (see chapter 12 (3)).

(2) Interface specifications

Electric characteristic : Based on EIA RS-232C
Connection signal

:

Cable length

: 15m or less

Connector

: D-SUB, 9-pin plug

Connection

: 1:1 connection

(3) Composition

12. SPECIFICATIONS FOR SERIAL TRANSMISSION (RS-232C)

Pin No.

Signal name

Meaning

Signal direction

2

RxD

Receive data

Input

3

TxD

Send data

Output

4

DTR

Data terminal relay

(Not used)

5

GND

Signal ground

6

DSR

Data set ready

(Not used)

7

RTS

Request to send

(Not used)

8

CTS

Clear to send

(Not used)

P

UX Meter

Host computer

Transmission cable

Non-isolation

15m

RxD

TxD

TxD

RxD

DTR

DTR

GND

GND

DSR

DSR

RTS

RTS

CTS

CTS

BULLETIN F-68