Operation – KROHNE MFC 300 EN User Manual
Page 80
6
OPERATION
80
MFC 300
www.krohne.com
02/2012 - 4000498602 - MA MFC 300 R03 en
A4 Station Address
A4
Station Address
For Profibus / FF / Modbus devices.
A5 Digital Outputs
A5
Digital Outputs
Valid for all pulse outputs (terminals A, B and/or D) and totaliser 1.
A5.1
Measurement
1) Select measurement: volume flow / mass flow / concentration flow 1
2) Use for all outputs? (also use this setting for Fct. A5.2...A5.5!)
Setting: no (only for pulse output D) / yes (for all digital outputs)
A5.2
Pulse Value Unit
Selection of the unit from a list, depending on the measurement.
A5.3
Value p. Pulse
1) Setting for pulse output D (volume or mass value per pulse)
Setting: xxx.xxx in l/s or kg/s
2) Use for all outputs? Make setting, see Fct. A5.1 above!
A5.4
Low Flow Cutoff
1) Setting for pulse output D (sets output value to "0")
Setting: x.xxx ± x.xxx% (range: 0.0…20%)
(1st value = switching point / 2nd value = hysteresis),
condition: 2nd value ≤ 1st value
2) Use for all outputs? Make setting, see Fct. A5.1 above!
A6 GDC IR interface
A6
GDC IR interface
After this function has been activated an optical GDC adapter can be
connected to the LC display. If approximately 60 seconds pass without a
connection being established or after the adapter is removed, then the
function is exited and the optical keys are active once again.
break (exit function without connection)
activate (the IR interface (adapter) and interrupt the optical keys)
A7 Zero Calibration
A7
Zero Calibration
Zero calibration, calibration sequence as described in Fct. C1.1.1...1.1.4
A8 Operation Mode
A8
Operation Mode
Set the operating mode.
Setting: measure / stop / standby
For detailed information refer to
Mode (menu A8) on page 98.
No.
Function
Settings / descriptions
.book Page 80 Monday, February 6, 2012 11:01 AM