Technical data – KROHNE MFC 300 EN User Manual
Page 136
8
TECHNICAL DATA
136
MFC 300
www.krohne.com
02/2012 - 4000498602 - MA MFC 300 R03 en
Operating conditions
Temperature
Temperature
Temperature
Temperature
Process temperature
Refer to technical data for the measuring sensor.
Ambient temperature
Depending on the version and combination of outputs.
It is a good idea to protect the converter from external heat sources such as direct
sunlight as higher temperatures reduce the life cycle of all electronic components.
-40...+65°C / -40…+149°F
Stainless steel housing: -40…+55°C / -40…+131°F
Ambient temperatures below -25°C / -13°F may affect the readability of the display.
Storage temperature
-50…+70°C / -58…+158°F
Pressure
Pressure
Pressure
Pressure
Medium
Refer to technical data for the measuring sensor.
Ambient pressure
Atmosphere
Media properties
Media properties
Media properties
Media properties
State of aggregation
Liquids, gases and slurries
Flow rate
Refer to technical data for the measuring sensor.
Other conditions
Other conditions
Other conditions
Other conditions
Protection category acc. to IEC
529/ EN 60529
C (compact version) & F (field housing):
IP66/67 (acc. to NEMA 4/4X)
W (wall-mounted housing):
IP 65 (acc. to NEMA 4/4x)
R (19" rack-mounted housing):
IP20 (acc. to NEMA 1)
Installation conditions
Installation
For detailed information, refer to chapter "Installation conditions".
Dimensions and weights
For detailed information refer to section "Dimensions and weights".
.book Page 136 Monday, February 6, 2012 11:01 AM