Technical data – KROHNE MFC 300 EN User Manual
Page 144
8
TECHNICAL DATA
144
MFC 300
www.krohne.com
02/2012 - 4000498602 - MA MFC 300 R03 en
Approvals and certificates
CE
The device fulfils the statutory requirements of the EC directives. The manufacturer
certifies that these requirements have been met by applying the CE marking.
Non-Ex
Standard
Hazardous areas
Hazardous areas
Hazardous areas
Hazardous areas
Option (only version C)
Option (only version C)
Option (only version C)
Option (only version C)
ATEX
II 2 G Ex d [ib] IIC T6....T1
II 2 G Ex de [ib] IIC T6....T1
II 2 D Ex tD A21 IP6x T160°C (dep. on the measuring sensor)
without heating jacket or sensor insulation
II 2 D Ex tD A21 IP6x T170°C (dep. on the measuring sensor)
with heating jacket and sensor insulation
II 2(1) G Ex d [ia/ib] IIC T6....T1
II 2(1) G Ex de [ia/ib] IIC T6....T1
II 2(1) D Ex tD [iaD] A21 IP6x T160°C (dep. on the measuring sensor)
without heating jacket or sensor insulation
II 2(1) D Ex tD [iaD] A21 IP6x T170°C (dep. on the measuring sensor)
with heating jacket and sensor insulation
Option (F version only)
Option (F version only)
Option (F version only)
Option (F version only)
ATEX
II 2 G Ex d [ib] IIC T6
II 2 G Ex de [ib] IIC T6
II 2(1) G Ex d [ia/ib] IIC T6
II 2(1) G Ex de [ia/ib] IIC T6
II 2 D Ex tD [ibD] A21 IP6x T80°C
II 2(1) G Ex tD [iaD/ibD] A21 IP6x T80°C
Nepsi
Ex de ib [ia/ib] IIC T6
Ex d ib [ia/ib] IIC T6
Option (only versions C and F)
Option (only versions C and F)
Option (only versions C and F)
Option (only versions C and F)
FM / CSA
Class I, Div 1 groups B, C, D
Class II, Div 1 groups E, F, G
Class III, Div 1 hazardous areas
Class I, Div 2 groups B, C, D
Class II, Div 2 groups F, G
Class III, Div 2 hazardous areas
IECEx
Ex zone 1 + 2
TIIS (in preparation)
Zone 1/2
Custody transfer
Custody transfer
Custody transfer
Custody transfer
None
Standard
Option
Liquids other than water 2004/22/EC (MID) acc. to OIML R 117-1
Other standards and approvals
Other standards and approvals
Other standards and approvals
Other standards and approvals
Shock and vibration resistance
IEC 68-2-3
Electromagnetic compatibility
(EMC)
2004/108/EC in conjunction with EN 61326-1 (A1, A2)
European Pressure Equipment
Directive
PED 97/23 (only for compact versions)
NAMUR
NE 21, NE 43, NE 53
.book Page 144 Monday, February 6, 2012 11:01 AM