beautypg.com

Electrical connections – KROHNE MFC 300 EN User Manual

Page 57

background image

ELECTRICAL CONNECTIONS

4

57

MFC 300

www.krohne.com

02/2012 - 4000498602 - MA MFC 300 R03 en

Pulse and frequency output passive P

N

NAMUR, modular I/O

• Connection in conformity with EN 60947-5-6
• open:

I

nom

= 0.6 mA

closed:
I

nom

= 3.8 mA

• X designates the connection terminals A, B or D, depending on the version of the signal

converter.

INFORMATION!

For frequencies above 100 Hz, shielded cables are to be used in order to reduce effects from
electrical interferences (EMC).

Compact and field housing versions:

Compact and field housing versions:

Compact and field housing versions:

Compact and field housing versions: Shield connected via the cable terminals in the terminal
compartment.
Wall-mounted version:

Wall-mounted version:

Wall-mounted version:

Wall-mounted version: Shield connected using 6.3 mm / 0.25" push-on connectors
(insulation to DIN 46245) in the terminal compartment.

Any connection polarity.

Figure 4-22: Pulse and frequency output passive P

N

to NAMUR EN 60947-5-6

.book Page 57 Monday, February 6, 2012 11:01 AM