beautypg.com

Description of hart interface – KROHNE MFC 300 EN User Manual

Page 168

background image

9

DESCRIPTION OF HART INTERFACE

168

MFC 300

www.krohne.com

02/2012 - 4000498602 - MA MFC 300 R03 en

HART

Identification

Manufacturer

Rd

/ Model

Rd

/ Device ID

Rd

/

Address / Tag / Date / Message / Description /
Write Protect

Rd

/ Final Assembly No. / Sensor Serial No.

Revision Numbers

Universal Rev.

Rd

/ Device Rev.

Rd

/

Software Rev.

Rd

/ Hardware Rev.

Rd

Preambles

Request Preams

Rd

/ Response Preams

Dynamic Variables

PV is

Rd

/ SV is / TV is / 4V is

HART units

Units

Volume Flow / Mass Flow /

Flow Velocity / Conductivity /

Temperature / Totaliser 1 / Totaliser 2 /
Totaliser 3

Opt

/ Concentration 1

Opt

/

Concentration 2 or Diagnosis 3

Opt

/

Concentration Flow 1

Opt

/ Concentration Flow 2

Opt

/

Diagnosis 1

Opt

/ Diagnosis 2

Opt

HART Format

Display Formats

Volume Flow

Loc

/ Mass Flow

Loc

/

Flow Velocity

Loc

/ Density

Loc

/

Temperature

Loc

/ Totaliser 1

Loc

/ Totaliser 2

Loc

/

Totaliser 3

Opt, Loc

/ Concentration 1

Loc

/

Concentration 2 or Diagnosis 3

Loc

/

Concentration Flow 1

Loc

/ Concentration Flow 2

Loc

/

Diagnosis 1

Loc

/ Diagnosis 2

Loc

Service

Access Level HART

Rd

Compare and Clear Offline

Status / Conditions

Overview

Standard

Primary variable out of limits

Non-primary variable out of limits

Primary variable analog output saturated

Primary variable analog output fixed

Field Device Cold Start

Malfunction

Configuration changed

Failure (device)

F Device Error / F IO1 / F Parameter / F IO2 / F Configuration / F Display /

F Sensor: Global Data Error / Sensor: Local Data Error / F SE Data Error /

F SE Drive Failure / F SE Hardware Failure / F SE Data Different /

F SE Defective / F Interface PCB Failure / F SE Wiring Error /

F 2 Phase Flow / F Fieldbus /

F Current Output A / F Current Output B / F Current Output C /

F SW User Interface / F Hardware Settings / F Hardware Detection /

F RAM/ROM Error IO1 / F RAM/ROM Error IO2

Failure (application)

F Application Error / F Tube Not Oscillating / F System Control /

F Open Circuit A / F Open Circuit B / F Open Circuit C /

F Wiring A / F Wiring B / F Sensor: Under Range /

F Stop Mode / F Sensor: System Error / F SE Comms. Failure /

F Over Range A (Current) / F Over Range B (Current) / F Over Range C /

F Over Range A (Pulse) / F Over Range B (Pulse) / F Over Range D /

F Active Settings / F Factory Settings / F Backup 1 Settings /

F Backup 2 Settings

.book Page 168 Monday, February 6, 2012 11:01 AM