DESCRIPTION OF HART INTERFACE

148

MFC 300

www.krohne.com

02/2012 - 4000498602 - MA MFC 300 R03 en

9.3 Connection variants

The signal converter is a 4-wire device with 4...20 mA current output and HART

®

interface.

Depending on the version, the settings and the wiring, the current output can operate as passive
or active output.

• Multi-Drop Mode is supported

Multi-Drop Mode is supported

Multi-Drop Mode is supported

Multi-Drop Mode is supported
In a Multi-Drop communication system, more than 2 devices are connected to a common
transmission cable.

• Burst Mode is not supported

Burst Mode is not supported

Burst Mode is not supported

Burst Mode is not supported
In the Burst Mode a slave device transfers cyclic pre-defined response telegrams, to get a
higher rate of data transfer.

There are two ways of using the HART

®

communication:

• as Point-to-Point connection and
• as Multi-Drop connection with 2-wire connection or

as Multi-Drop connection with 3-wire connection.

INFORMATION!
For detailed information about the electrical connection of the signal converter for HART

®

, see

the "Electrical connection" section.

.book Page 148 Monday, February 6, 2012 11:01 AM