beautypg.com

Technical data – KROHNE MFC 300 EN User Manual

Page 140

background image

8

TECHNICAL DATA

140

MFC 300

www.krohne.com

02/2012 - 4000498602 - MA MFC 300 R03 en

Passive

U

ext

≤ 32 VDC

-

f

max

in operating menu set to

f

max

≤ 100 Hz:

I ≤ 100 mA

open:

I ≤ 0.05 mA at U

ext

= 32 VDC

closed:

U

0, max

= 0.2 V at I ≤ 10 mA

U

0, max

= 2 V at I ≤ 100 mA

f

max

in operating menu set to

100 Hz < f

max

≤ 10 kHz:

I ≤ 20 mA

open:

I ≤ 0.05 mA at U

ext

= 32 VDC

closed:

U

0, max

= 1.5 V at I ≤ 1 mA

U

0, max

= 2.5 V at I ≤ 10 mA

U

0, max

= 5.0 V at I ≤ 20 mA

NAMUR

-

Passive to EN 60947-5-6

open:

I

nom

= 0.6 mA

closed:

I

nom

= 3.8 mA

Passive to EN 60947-5-6

open:

I

nom

= 0.43 mA

closed:

I

nom

= 4.5 mA

U

i

= 30 V

I

i

= 100 mA

P

i

= 1 W

C

i

=10 nF

L

i

~ 0 mH

Low flow cut off

Low flow cut off

Low flow cut off

Low flow cut off

Function

Switching point and hysteresis separately adjustable for each output, counter and

the display

Switching point

Set in increments of 0.1.

0…20% (current output, frequency output)

Hysteresis

Set in increments of 0.1.

0…5% (current output, frequency output)

Time constant

Time constant

Time constant

Time constant

Function

The time constant corresponds to the elapsed time until 67% of the end value has

been reached according to a step function.

Settings

Set in increments of 0.1.

0…100 s

.book Page 140 Monday, February 6, 2012 11:01 AM