beautypg.com

Training profiles – Lincoln Electric IM8002 POWER WAVE MANAGER User Manual

Page 98

background image

Chapter 11. Training

Training Profiles

11.4

Power Wave® Manager User Manual

IM8002

Training Profiles

Be sure you are connected to the Welding Power Source on which you want to train the welds and that all

components are working properly.

STOP |

Be sure you have read Before You Begin Training a Weld

on page 11.1 before you continue.

Figure 11.1 Weld Training Window

For any Weld Profiles in the list with existing limits, green icons appear that represent each limit recorded

for that profile: WeldScore ( ), Time ( ), Amperage ( ), Voltage ( ), and Wire Feed Speed ( ).

If the Weld Profile contains an active limit (i.e., a check mark in the Enabled checkbox) with

values greater than zero (0), the green icon appears next to that Weld Profile number.

If the WeldScore™ limit is not enabled and there is a value entered in the field, the icon

appears but is gray.

If a limit is not enabled or the value for the limit is zero (0), the icon does not appear.

TIP

|

Generally when you create a training model for a Weld

Profile, only the WeldScore, Time and Wire Feed Speed

icons appear, and sometimes only the WeldScore icon,

depending on how you have chosen to use the Weld Profile.