Chapter 6. Power Source Settings

Cable Settings and Tests

6.6

Power Wave® Manager User Manual

IM8002

Figure 6.4 Sense Lead Diagnostics

NOTE |

You cannot perform this test with ServoTorch.

Automatic Test

Power Wave® Manager can also help you troubleshoot sense lead issues. The software automatically

attempts to detect the sense lead location by turning on the Welding Power Source’s output in an

open circuit voltage (OCV) mode and reading back voltage. The system does this while stepping

through the various manual sense lead locations, determining which location is most likely the one

being used.

STOP |

Make sure your welding circuit is open before performing

this test.

To perform the automatic test, choose the Detect sense lead location automatically option in Power

Wave® Manager and click the Test sense lead selection button.