Cable settings and tests, Sense lead settings tab – Lincoln Electric IM8002 POWER WAVE MANAGER User Manual
Page 37

Cable Settings and Tests
Chapter 6. Power Source Settings
IM8002
Power Wave® Manager User Manual
6.3
Cable Settings and Tests
The Cable settings and tests section allows you to configure and test your welding cables and sense leads
for the Welding Power Source to which you are connected.
Sense Lead Settings Tab
Use these settings to enable or disable automatic hardware sense lead selection or to modify the behavior
through manual settings. For most applications, the Automatic hardware sense lead selection is the best
method to use. This method reduces the chance of fairing and losing tips due to sense lead losses.
NOTE |
The Sense lead settings tab is only available for those
Welding Power Sources that do not have DIP switches for
modifying the sense lead location. The settings are also not
available for Welding Power Sources that do not support
changing the sense lead selection.
Figure 6.2 Sense Lead Settings Tab
Enabling Work Sense Lead
You can configure the system to force sense arc voltage from the work sense lead (21 lead) instead of
the negative output stud. This requires connecting to the voltage sense connector and attaching the
work lead to the work.
To enable the work sense lead:
Procedure
Details
1.
Remove the check mark from the Automatic
hardware sense lead selection checkbox.
2.
Place a check mark in the Enable remote
voltage sense leads checkbox.
3.
Click the Apply settings button.