Chapter 10. Production Monitoring
Configuration
10.8
Power Wave® Manager User Manual
IM8002
Figure 10.6 Profile Limits Tab
To change settings in a particular Weld Profile, simply click the Weld Profile to select it and make changes
to the fields on the right. Place a check mark in the Enable checkbox to tell the power source to use that
limit for the profile. (If the values are zero (0) or there is no check mark next to Enable, the system
automatically ignores the limit.) Remember to click the Apply settings button to commit your changes.
Table 10.3 explains each of the limits available.
NOTE |
When you enable the Minimum WeldScore option, you can
only set the Weld duration limit and/or the Wire feed speed
limit. Since you must train a weld in order for WeldScore™
to be effective, the trained weld already includes the
amperage and voltage limits.
Next to each Weld Profile in the list are icons that represent each limit available in that Weld Profile:
WeldScore ( ), Time ( ), Amperage ( ), Voltage ( ), and Wire Feed Speed ( ).
If the Weld Profile contains an active limit (i.e., a check mark in the Enabled checkbox) with
values greater than zero (0), the green icon appears next to that Weld Profile number.
If the WeldScore™ limit is not enabled and there is a value entered in the field, the icon appears
but is gray.
If the limit is not enabled or the value for the limit is zero (0), the icon does not appear.
TIP
|
If you have made changes to a Weld Profile and have not
clicked the Apply settings button, the gray icon ( ) at the
beginning of the Weld Profile changes to a red icon ( ).