beautypg.com

Lincoln Electric IM8002 POWER WAVE MANAGER User Manual

Page 86

background image

Chapter 10. Production Monitoring

Configuration

10.8

Power Wave® Manager User Manual

IM8002

Figure 10.6 Profile Limits Tab

To change settings in a particular Weld Profile, simply click the Weld Profile to select it and make changes

to the fields on the right. Place a check mark in the Enable checkbox to tell the power source to use that

limit for the profile. (If the values are zero (0) or there is no check mark next to Enable, the system

automatically ignores the limit.) Remember to click the Apply settings button to commit your changes.

Table 10.3 explains each of the limits available.

NOTE |

When you enable the Minimum WeldScore option, you can

only set the Weld duration limit and/or the Wire feed speed

limit. Since you must train a weld in order for WeldScore™

to be effective, the trained weld already includes the

amperage and voltage limits.

Next to each Weld Profile in the list are icons that represent each limit available in that Weld Profile:

WeldScore ( ), Time ( ), Amperage ( ), Voltage ( ), and Wire Feed Speed ( ).

If the Weld Profile contains an active limit (i.e., a check mark in the Enabled checkbox) with

values greater than zero (0), the green icon appears next to that Weld Profile number.

If the WeldScore™ limit is not enabled and there is a value entered in the field, the icon appears

but is gray.

If the limit is not enabled or the value for the limit is zero (0), the icon does not appear.

TIP

|

If you have made changes to a Weld Profile and have not

clicked the Apply settings button, the gray icon ( ) at the

beginning of the Weld Profile changes to a red icon ( ).