Miscellaneous tab – Lincoln Electric IM8002 POWER WAVE MANAGER User Manual
Page 93

Configuration
Chapter 10. Production Monitoring
IM8002
Power Wave® Manager User Manual
10.15
power source will generate an e-mail. If the Weld Operator completes the next weld and the
WeldScore™ is again below the minimum, the power source generates another e-mail.
To assign an e-mail trigger to an e-mail address, simply make sure you have the e-mail address
selected and place a check mark in the checkbox next to the appropriate options. Table 10.6 explains
each one in a little more detail.
Table 10.6 E-mail Triggers
Field
Description
System event
When a System Event occurs within the Welding Power Source (e.g., a
thermostat fault), when it is reprogrammed with new software, or when one of
its hardware components is replaced, removed, or added, the power source
sends an e-mail if there is a check mark next to this option.
Service event
To trigger an e-mail to this e-mail address when a service event occurs, place a
check mark next to this option. The power source uses these events for
specific troubleshooting and reports them during general operation.
Weld Profile limit
exceeded
When a completed weld has exceeded one or more of the limits defined in a
given Weld Profile, the power source sends an e-mail message.
Wire package
warning
When the consumable package reaches the limit set in the Warning weight
field (page 10.11), the power source sends an e-mail to this address when
there is a check mark next to this option.
Power on
Choosing this trigger causes the power source to send out an e-mail when the
power source is turned on or reset.
Sending an E-mail Test
Once you have established your e-mail settings and entered the person’s address into Power Wave®
Manager, you can test the e-mail address to make sure the recipient receives e-mail notifications
properly.
To test the e-mail settings, simply click the address in the E-mail address list and click the Send test e-
mail button. The Welding Power Source attempts to send out an e-mail as soon as you click the test
button, but the amount of time it takes for the recipient to receive the e-mail depends on the e-mail
server in your company. If the recipient hasn’t received the e-mail within about half an hour, verify
the address and try again, or contact your IT administrator for assistance.
Miscellaneous Tab
The Miscellaneous tab displays the part serial number, operator ID and consumable lot number currently
being used by the Welding Power Source for the welds that it makes. These numbers can come
automatically from a robotic system, an external controller, or the mobile app, but you can update the
numbers manually in Power Wave® Manager if necessary.