Chapter 7. Network Settings

Ethernet

7.16

Power Wave® Manager User Manual

IM8002

For example, if the custom range is from 192.168.1.0 to 192.168.1.255, a computer whose IP address

is 192.168.1.10 will be able to access this machine, but a computer whose IP address is 192.168.2.1

will not.

Communications Setup Tab

Network speed (how fast your network can transmit data) and the duplex setting (the two-way

communication allowed on that network) dictate how effective the communication is between your

Welding Power Source and the network. The speed and duplex of the Welding Power Source should

match the speed and duplex of your network. Welding Power sources are shipped with default

settings that operate properly with most networks. You typically do not need modify this setting.

Figure 7.15 Communication Setup Tab

You have the following options if you ever need to make adjustments:

100 BaseT, Full Duplex (default)

10 BaseT, Full Duplex

100 BaseT, Half Duplex

10 BaseT, Half Duplex

STOP |

Assigning an incorrect network speed and duplex on the

Welding Power Source may cause it to become unreachable

on the network. If you are unsure about what values to

assign to the Welding Power Source, consult your network

administrator.