beautypg.com

Settings tab – Lincoln Electric IM8002 POWER WAVE MANAGER User Manual

Page 77

background image

Observer

Chapter 9. Tools

IM8002

Power Wave® Manager User Manual

9.11

Field

Description

Average amps

Hundreds of times per second, the Welding Power Source takes a measurement of

the arc current being used while the welder is active for this weld. When the weld

is complete, the power source averages those measurements together. The

Average amps column displays that average value for this weld.

Average volts

Hundreds of times per second, the Welding Power Source takes a measurement of

the arc voltage being used while the welder is active for this weld. When the weld

is complete, the power source averages those measurements together. The

Average volts column displays that average arc voltage value for this weld.

Settings Tab

The Settings tab allows you to identify which weld sequencer states are modified when you change

a welding setting on the Charts tab (such as Workpoint or Trim). Place a check mark next to the

appropriate states.

NOTE |

In order to see a parameter in the charts for the weld, you

must choose the signal before you begin welding. Adding

the signal after completing the weld does not create any

data to display.

Figure 9.10 Settings Tab

If you want to control the machine’s output from within Power Wave® Manager, place a check mark next to

the Show Output ON/OFF button option. This displays a button in the toolbar allowing you to turn the

output of the Welding Power Source on or off. For safety, you must press and hold the Ctrl key on the

keyboard while clicking the button in order for it to turn the power source on or off.

STOP |

Use extreme caution when controlling the output from

Power Wave® Manager. The output does not automatically

shut off if you change screens or exit Power Wave®

Manager.