Deleting a trained weld from a weld profile, Clearing training data – Lincoln Electric IM8002 POWER WAVE MANAGER User Manual
Page 102

Chapter 11. Training
Deleting a Trained Weld from a Weld Profile
11.8
Power Wave® Manager User Manual
IM8002
Deleting a Trained Weld from a Weld Profile
When you perform welds to create training models, you may accidentally create a weld that is not an
acceptable example. You may also have an existing trained weld in a Weld Profile that throws off the limits
for that profile. Power Wave® Manager allows you to remove individual training files from the Weld
Profile.
STOP |
You cannot undo this action. Once you select Delete
training weld data file from the pop-up menu, the file is
deleted from the Weld Profile.
Procedure
Details
1.
Right-click the Weld Profile.
2.
Select Delete training weld data file from the
pop-up menu.
3.
Click OK when prompted to delete the file.
4.
Click the Apply settings button.
Power Wave® Manager saves the changes to the
Welding Power Source.
Clearing Training Data
There may be times when you need to start over with a Weld Profile or you just need to remove all of the
training data for the profile. You can clear the training data, as well as any limits you entered manually on
the Profile limits tab under Production Monitoring > Configuration.
To clear data for a Weld Profile:
Procedure
Details
1.
Right-click the Weld Profile.
2.
Select Remove all welds and clear the
training model from the pop-up menu.
3.
Click OK to confirm you want to clear
the data.
Power Wave® Manager clears data on the Welding
Power Source and resets the machine.
NOTE |
This process could take some time.
Power Wave® Manager disables certain functions
until the process is complete.
4.
Click OK when prompted that the machine
has been reset.