beautypg.com

Logged welds tab – Lincoln Electric IM8002 POWER WAVE MANAGER User Manual

Page 76

background image

Chapter 9. Tools

Observer

9.10

Power Wave® Manager User Manual

IM8002

TIP

|

To save the data in the charts to a tab-delimited text file,

click the Save chart data button on the top toolbar. Click

the Clear charts button to clear the data from the screen

and start fresh.

TIP

|

Click the plus icon ( ) at each corner of the chart to

collapse the panel next to it (if available).

Logged Welds Tab

The Logged Welds tab displays a list of the welds that were made during the Observer session. The

Observer session begins when you click into the Observer section of Power Wave® Manager. The session

ends when you close Power Wave® Manager or disconnect the power source. Each weld that you create

during this time appears on the Logged welds tab when the Welding Power Source’s output turns off after

you complete the weld.

Figure 9.9 Logged Welds Tab

TIP

|

To save the log to a tab-delimited text file, click the Save

weld log button on the top toolbar. To clear the log, click

the Clear weld log button.

Table 9.1

Columns on the Logged Welds Tab

Field

Description

Date/time

This column represents the date and time that the weld began.

Duration (s)

This column represents the length of time (in seconds) from the time listed in the

Date/time column to the time the Welding Power Source stopped welding.

Weld mode

This column displays the number of the Weld Mode used for this weld.

Workpoint

This column displays the value of the workpoint variable for this weld.

WeldScore™

The application displays the WeldScore™ for this weld. A value appears here only if

you used a Weld Profile for this weld and there was a training model created for

that Weld Profile.