Lincoln Electric IM8002 POWER WAVE MANAGER User Manual
Page 36

Chapter 6. Power Source Settings
Calibration
6.2
Power Wave® Manager User Manual
IM8002
The following is the recommended procedure for calibrating your power source:
Procedure
Details
1.
Attach Welding Power Source output cables
to a 300A/30V resistive grid load.
2.
Open Power Wave® Manager.
3.
Connect to the power source.
4.
Display the Calibration section.
5.
Click the Turn output ON button.
The Turn Output ON button enables the output
of the Welding Power Source. When you turn
the output on, the indicator will begin to flash red
( ), and values will appear under Feedback for:
Output amperage, Output voltage, Capacitor
voltages and Voltage sense location.
6.
Use the plus and minus icons ( and ) to
the right of Amperage adjust (Figure 6.1) to
calibrate the Welding Power Source to the
value you set in Power Wave® Manager.
This adjusts the actual measured values on the
Welding Power Source to match Power Wave®
Manager.
7.
Use the plus and minus icons ( and ) to
the right of Voltage adjust (Figure 6.1) to
calibrate Power Wave® Manager to the
Welding Power Source.
This adjusts the feedback in Power Wave®
Manager to match the Welding Power Source.
STOP |
Do not calibrate voltage at voltages
greater than 50V.
8.
Click the Turn output OFF button.
The Turn Output OFF button disables the Welding
Power Source’s output.