Miscellaneous – Lincoln Electric IM8002 POWER WAVE MANAGER User Manual
Page 41

Miscellaneous
Chapter 6. Power Source Settings
IM8002
Power Wave® Manager User Manual
6.7
Manual Test
If you know want to step through each sense lead manually, you can use Power Wave® Manager to
test them individually and force the Welding Power Source to sense voltage from the location you
choose.
To perform the test, choose the Select sense lead location manually option and choose one of the
following options. Click the Apply settings button to confirm your choice and click the Test sense lead
selection button to perform the test. Repeat for each option you want to test.
Output studs: This configuration utilizes arc voltage sensing from inside the Welding Power
Source and does not require polarity to be configured.
67 Positive or 67 Negative: Choose the option depending on the welding polarity in which your
system is configured to operate.
67 and 21: Use this option to test both remote voltage sense leads.
STOP |
When you have completed testing, cycle the power to the
Welding Power Source (off then back on) to clear any
changes made to the voltage sense location. Be careful that
no welding is currently in progress.
Miscellaneous
In the Miscellaneous section under Power source settings, you can synchronize the date and time on the
power source. You can also see the lifetime arc time for the power source. You can also set a couple of
options for the selected weld controller.
NOTE |
Anytime you make changes to the options in this section,
be sure you click the Apply settings button to commit your
changes.
Figure 6.5 Miscellaneous Section