Ethernet

Chapter 7. Network Settings

IM8002

Power Wave® Manager User Manual

7.15

Simply choose the Obtain an IP address automatically option if you want the Welding Power Source to

assign the IP address automatically using a dynamic IP address.

STOP |

If you choose this option, the Welding Power Source

obtains a different IP address every time it connects

to a network.

If you want to assign a specific address to this Welding Power Source, choose the Use the following IP

address option and enter the appropriate information. (Table 7.3 on page 7.14 explains these fields in

more detail.)
Once you have configured the network settings, click the Apply settings button and cycle the power to

the Welding Power Source (off then back on) in order for the new settings to take effect.

NOTE |

If you have modified the Welding Power Source’s IP address

and would like to modify more settings, you will need to

connect to the Welding Power Source using the new

address. (See page 4.1 for connecting to a power source.)

TIP

|

If you cannot connect to the Welding Power Source, refer to

Appendix A for troubleshooting options.

Network Security Sub-Tab

The Network Security tab allows the configuration of a range of IP addresses that are allowed to

connect to the Welding Power Source, as well as another range of addresses that are allowed to

modify parameters on the Welding Power Source (the latter range is a subset of the first). This

provides some control over the components and modules (e.g., controllers, wire feeders, user

interfaces) that can connect to this Welding Power Source.

Figure 7.14 Network Security Tab

For each of the two ranges, the user can select either all addresses, addresses only within the

machine’s subnet, or a custom range of addresses.