Aclconfig – Brocade Virtual ADX XML API Programmer’s Guide (Supporting ADX v03.1.00) User Manual
Page 669
Brocade Virtual ADX XML API Programmer’s Guide
659
53-1003248-01
Data structures
6
AclConfig
This structure is a high-level description of ACL configuration.
systemResetInterval
unsignedInt
Optional
This parameter is
mandatory when
the
systemThreshold
parameter is
present. The valid
value range is
from 1 to 30
minutes.
Specifies the
number of
minutes that the
device enforces
the drop or
forward action
after a system
level threshold
has been
exceeded.
interfaceThreshold
unsignedInt
Optional
The valid value
range is from 300
to 8000.
The default value
is 4000.
Sets the threshold
for individual
interfaces
interfaceExceedAction
aclFragmentRateExceedActionEnum
Optional
This parameter is
mandatory when
the
interfaceThreshol
d parameter is
present.
Specifies the
action to take if
the interface level
threshold (
parameter) is
exceeded.
interfaceResetInterval unsignedInt
Optional
This parameter is
mandatory when
the
interfaceThreshol
d parameter is
present. The valid
value range is
from 1 to 30
minutes.
Specifies the
number of
minutes within
which the device
enforces the drop
or forward action
after a interface
level threshold
has been
exceeded.
TABLE 256
Attributes
Name
Type
Presence
Rules
Description
disableAcl
boolean
Optional
The default value is
FALSE.
Enables or disables the use of
ACL.
enableIpv4FlowBasedAcl
boolean
Optional
The default value is
FALSE.
Enables or disables the
backward compatibility for
IPV4 ACL processing.
enableIpv6FlowBasedAcl
boolean
Optional
The default value is
FALSE.
Enables or disables the
backward compatibility for
IPV6 ACL processing.
disableGlobalLogging
boolean
Optional
The default value is
FALSE.
Enables or disables the ACL
global logging.
TABLE 255
Attributes (Continued)
Name
Type
Presence
Rules
Description