<7. Standard Specifications>
7-2
IM 21B04C01-01E
Span Adjustment Range:
Within 300% of span
Valve-stem Travel Range:
Linear Motion:
10 to 100 mm (0.4 to 4.0 inch)
(Rotation Range: ±10 to ±25 deg)
Rotary Motion:
20 to 90 deg
Air Consumption and Output Capacity:
Diaphragm, Single Acting Cylinder
Maximum Air
Consumption
0.20 SCFM (0.32 Nm
3
/h) at 140 kPa
Maximum Output
Capacity
4.1 SCFM (6.6 Nm
3
/h) at 140 kPa
Double Acting Cylinder
Maximum Air
Consumption
0.62 SCFM (1.0 Nm
3
/h) at 400 kPa
Maximum Output
Capacity
8.5 SCFM (13.7 Nm
3
/h) at 400 kPa
Ambient Temperature Limits:
Single Acting Actuator:
–40 to 85°C (–40 to 185°F)
Double Acting Actuator:
–40 to 60°C (–40 to 140°F) for standard
–10 to 85°C (14 to 185°F) for high
temperature use with option code /HT
Ambient Humidity Limits:
5 to 95% RH at 40°C (104°F)
EMC Conformity Standards:
,
EN61326-1 Class A, Table 2 (For use in
industrial locations)
Degrees of Protection:
IP65, NEMA4X
Connections:
Air Connection: Rc 1/4 or 1/4 NPT female
Electrical Connection: G 1/2, 1/2 NPT, M20 and
Pg13.5 female
Pressure Gauge Connection:
Pressure
gauge
connection
With pressure
gauge
(Optional)
Connections
Codes
1,5
and
6
Rc 1/8 female /GP, /GM, and /GB
3
1/8 NPT
female
/GE
Mounting:
Front of Actuator with bracket.
Direct Connection for rotary valve.
Weight:
Single Acting Actuator: 2.4 kg (5.3 lb)
Double Acting Actuator: 2.8 kg (6.2 lb)
Performance Specifications
Linearity:
Single Acting Actuator:
±0.5% of Span (including linkages)
Double Acting Actuator:
±1.0% of Span (including linkages)
Hysteresis:
Single Acting Actuator: 0.3% of Span
Double Acting Actuator: 0.5% of Span
Ambient Temperature Effect:
±0.08% of Span/°C
Position Effect:
±0.3% of Span/90 deg
Vibration Effect:
±2% of Span at 2G (15 to 2000 Hz)