75

DeviceNet Gateway


Command name

CH+

PLC output (request)

PLC input (response)

+2 1046H

3

Position number

Same as the requested
value, if the command was
successful.

4

0

Deceleration data *4

5 0
6

Axis number 0 to FH *1

7 (RSV)

Read a
deceleration

8 (RSV)

Same as the requested
value, if the command was
successful.

+2 1047H

3

Position number

Same as the requested
value, if the command was
successful.

4

0

0000 ~ 00FFH (00FH:
Maximum current)

5 0
6

Axis number 0 to FH *1

7 (RSV)

Read a current-
limiting value for
push-motion
operation *5

8 (RSV)

Same as the requested
value, if the command was
successful.

+2 1048H

3

Position number

Same as the requested
value, if the command was
successful.

4

0

0000 ~ 00FFH (00FH:
Maximum current)

5 0
6

Axis number 0 to FH *1

7 (RSV)

Read a load
current threshold

8 (RSV)

Same as the requested
value, if the command was
successful.

*1) Axis numbers 0 to 15 correspond to data 00 to 0FH, respectively.
*2) Signed 32-bit integer data
*3) 32-bit integer data
*4) Eight-bit integer data
*5) Valid only with position table numbers under which a push-current limiting value other than zero

is set (= push-motion operation is set).