IAI America RCM-GW-DV User Manual

Page 62

background image

56

DeviceNet Gateway

Signal type

Bit

Signal

name

Description Details

Positioning

band

24-bit

data

---

Set a 24-bit integer (unit: 0.01 mm) based on
hexadecimal notation
Example) To specify +25.4 mm, set “0009ECH”

(“2540” in decimal notation).

(Notes)

Set position data within the soft stroke limits.
Specify the direction of push-motion operation

using DIR.

Even if positioning band is not set, the setting of

parameter No. 10, “Default positioning band” will
not be applied.

7.3 (4)

b15

---

Cannot be used.

---

b14 DIR

Push direction specification
(0 = Home return direction,
1 = Opposite to home return direction)

7.3 (4)

b13 PUSH

Push-motion

operation

mode specification

7.3 (4)

b12

SON

Servo on command

7.2 (7)

b11

STP

Pause command

7.2 (5)

b10

HOME

Home return command

7.2 (8)

b9

CSTR

Start command

7.2 (9)

PLC output

Control

signal

b8

RES

Reset command

7.2 (4)

b15-8

---

Cannot be used.

---

b7

EMGS

Emergency stop status

7.2 (2)

b6

PSFL

Missed work

7.3 (4)

b5

PWR

Controller ready

7.2 (1)

b4

SV

Ready (servo is on)

7.2 (7)

b3 MOVE

Moving

7.2

(6)

b2

HEND

Home return complete

7.2 (8)

b1

PEND

Position complete

7.2 (10)

Status

signal

b0 ALM

Alarm

7.2

(3)

Current

position

data

24-bit

data

---

The current position data is output as a signed 24-
bit integer (unit: 0.01 mm) based on hexadecimal
notation
Example) To specify +25.4 mm, set “0009ECH”

(“2540” in decimal notation).

(Note)

A negative value is indicated by a two’s

complement. Accordingly, the most significant bit
becomes “1.”

7.3 (4)

PLC input

---

b15-8

---

Cannot be used.

---